欢迎光临广州君达仪器仪表有限公司官方网站

关于君达 联系我们

联系电话:400 892 1718

手机微信:13602481136

当前位置:网站首页 >>电子测量仪器 >> 详细介绍

吉时利KEITHLEY TSG4102A/TSG4104A射频矢量信号发生器/泰克Tektronix TSG4106A

 

产品详情

The TSG4100A Series RF Vector Signal Generator offers mid-range performance and up to 200 MHz modulation bandwidth at an entry-level RF signal generator price. They use a new technique to provide spurious free outputs with low phase noise (-113 dBc/Hz at 20 kHz offset from 1 GHz carrier) and extraordinary frequency resolution (1 μHz at any frequency). The TSG4100A Series comes standard with analog modulation. Convenient, in-field software upgrades allow for easy transition from analog to more advanced vector and digital modulation capabilities, providing the most flexible configuration and best CAPEX protection. These instruments complement other leading mid-range RF test solutions from Tektronix, such as the USB-based RSA306 Spectrum Analyzer and MDO4000B and MDO3000 Mixed Domain Oscilloscopes.

The TSG4100A Series instruments use an ovenized SC-cut oscillator (TSG410xA-M00 or E1 models) time-base, providing a 100 X improvement in stability (and a 100 X reduction in the in-close phase noise) compared to instruments that use a TCXO time-base.

TSG4102A950 kHz to 2.0 GHz
TSG4104A950 kHz to 4.0 GHz
TSG4106A950 kHz to 6.0 GHz

Key features
  • Analog and vector/digital signal generation capabilities
  • Dual baseband ARB generators
  • Analog modulation standard
  • Soft key upgrade to vector/digital modulation at very low cost
  • Digital modulation applications for GSM, EDGE, W-CDMA, APCO-25, DECT, NADC, PDC, and TETRA
  • USB, GPIB, RS-232, and LAN interfaces
  • 12 pounds (5.6 kg)
  • 2U high and half standard rack width

 

Key performance specifications
  • True DC to 2 GHz, 4 GHz or 6 GHz to support both analog and vector/digital signal generation
  • Typical ≤±0.30 dB amplitude accuracy (0 dBm CW signal at 22 ºC) from 10 MHz to 6 GHz
  • I/Q modulation inputs (400 MHz RF bandwidth)
  • ASK, FSK, MSK, PSK, QAM, VSB, and custom I/Q

Analog modulation

The Tektronix TSG4100A Series RF Vector Signal Generators offer a wide variety of modulation capabilities. Modes include amplitude modulation (AM), frequency modulation (FM), phase modulation (ΦM), and pulse modulation. There is an internal modulation source as well as an external modulation input. The internal modulation source produces sine, ramp, saw, square, and noise waveforms. An external modulation signal may be applied to the rear panel modulation input. The internal modulation generator is available as an output on the rear panel.

Vector modulation

The TSG4100A Series builds on this performance by adding full support for vector signal modulation on RF carriers between 400 MHz and 6.0 GHz. It features a dual arbitrary waveform generator operating at 125 MHz for baseband signal generation. The generator has built-in support for the most common vector modulation schemes: ASK, QPSK, DQPSK, π/4 DQPSK, 8PSK, FSK, CPM, QAM (4 to 256), 8VSB, and 16VSB. It also includes built-in support for all the standard pulse shaping filters used in digital communications: raised cosine, root-raised cosine, Gaussian, rectangular, triangular, and more. Lastly, it provides direct support for the controlled injection of additive white Gaussian noise (AWGN) into the signal path.

Internal baseband generators

Using a novel architecture for I/Q modulation, the TSG4100A Series provides quick, user-friendly waveform generation. The baseband generator supports the playback of pure digital data. It automatically maps digital symbols into a selected I/Q constellation at symbol rates of up to 6 MHz and passes the result through the selected pulse shaping filter to generate a final waveform updated in real time at 125 MHz. This baseband signal is then modulated onto an RF carrier using standard IQ modulation techniques.

Digital communications protocols (GSM, GSM EDGE, W-CDMA, APCO-25, DECT, NADC, PDC, and TETRA) quickly configure the signal generator to the correct modulation type, symbol data rates, TDMA duty cycles, and digital waveform filters. The preset protocols also configure the rear-panel TDMA, START of FRAME, and SYMBOL CLOCK digital outputs. The baseband generators can be configured for these protocols without the use of external computers or third party software.

The I/Q waveforms are computed in real time. Symbols are mapped to constellations, digitally filtered, and up-sampled to 125 Msps to drive the I/Q modulator via dual 14-bit DACs. The symbols can be a fixed pattern, PRBS data from an internal source, or come from a downloaded user list of up to 16 Mbits.

The constellation mapping can be modified by the user. Digital filters include raised cosine, root raised cosine, Gaussian, rectangular, linear, sinc, and user-defined FIR.

External IQ modulation

The rear-panel BNC I/Q modulation inputs and outputs enable arbitrary vector modulation via an external source. The external signal path supports maximally 400 MHz of RF bandwidth with a full scale range of ±0.5 V and a 50 Ω input impedance.

Power vs. frequency

All TSG4100A Series models have cascaded stages of amplifiers and digital attenuators to drive the RF output. Five stages can provide up to +25 dB of gain to -130 dB of attenuation in 156 digitally controlled steps. During factory calibration, the output power is measured at 32 frequencies per octave for each of the 156 attenuator steps to populate a memory matrix with about 40,000 elements. When set to a particular frequency and power, the instrument interpolates between these matrix elements to determine the best attenuator setting. An analog attenuator is used to provide 0.01 dB resolution between matrix elements and to compensate for residual thermal effects.

OCXO time-base

These instruments offer an oven-controlled crystal oscillator (OCXO) time-base. The time-base uses a third-overtone stress-compensated 10 MHz resonator in a thermostatically controlled oven. The time-base provides very low phase noise and very low aging.

Easy remote communications

Remote operation is supported with RS-232, LAN, and GPIB interfaces. All instrument functions can be controlled and read over any of the interfaces. Up to nine instrument configurations can be saved in non-volatile memory.

推荐产品

Our Products
致远功率分析仪PA6000H/PA5000H/PA8000/PA2000mini带宽高达5M、采样率可达2MS/s,测量高达500次谐波,PA8000认证级功率分析仪,PA6000H、PA5000H 企业级功率分析仪,PA2000mini 便携式功率分析仪,可以满足您在功率测量方面的所有需求
日置HIOKI 3511-50 LCR测试仪测量频率1kHz/120hz,日置HIOKI 3511-50 LCR测试仪5ms快速测量LCR表,LCR测试仪HIOKI 3511-50 LCR表高精度±0.08%
超声波探伤仪TUD320数字超声波探伤仪,TUD320超声波探伤仪彩色高速宽温工业级TFT_LCD液晶显示,时代TUD320探伤仪检波方式有正半波、负半波、全波和射频四种方式可供选择
日本日置HIOKI 3285-20交直流钳型表启动电流峰值测量,交直流钳型表3285-20有效值测量DC、AC电流2000A,交直流钳型表HIOKI 3285-20电阻、连续性检查功能
地址:广州市越秀区寺右新马路4-8号长城大厦1213房
本站为原创设计 已做镜像备份 抄袭必究 粤ICP备08014908号
CopyRight © 1999-2026 君达仪器 版权所有
立即登录

会员注册

忘记密码
注册成为广州君达仪器会员
* 手机号码
* 登录密码
* 确认密码
* 公司名称
* 真实姓名
* 关注产品
* 联系邮箱
* 请选择您的性别
* 短信验证

点击获取短信验证码

立即注册账户

X
会员修改密码
* 手机号码
* 登录密码
* 确认密码
* 短信验证

点击获取短信验证码

立即修改密码

X